Evocycler™ / Rapid Thermal Cycling System..
 

Rapid cycling, instant results. No more agarose gels!

Evocycler™ is a new concept in thermal cycler technology, combining experimental design with rapid amplification and end-point product analysis in one straightforward system. From simple preparative amlification and product validation through to SNP analysis and genotyping the Evocycler™ provides results, fast.

Rapid cycling with Exceptional Linearity

Evogen™ has moved away from the conventional slower peltier based technology, to design an efficient heating and cooling mechanism, which offers exceptionally linear heating and cooling dynamics. This technology coupled with the design of a unique high performance tube with ultra-thin walls and a high surface to volume ratio, yields ultra-rapid and uniform cycling performance.



 
Optimised Tube Design

Superior Temperature Uniformity

Minimal Sample Lag

Improved Cycling times

Can be used with multiple chemistries and does not require BSA

Variable volumes of between 10µl and 100µl, for greater experimental flexibility.

Straight forward loading with standard pipette tips

Easy handling and storage.
 
 
Technical Specifications
Sample Capacity 12 wells
Sample Volume 10µl - 100µl
Footprint 300 x 170 x 210mm (W x H x D)
11 ¾ x 6¾ x 8¼inches (W x H x D)
Weight 5kg/11lb
Heating - Ramp rates Max 5°C/sec, Min 0.05°C/sec
Method of Heating/Cooling Circulating air(subject to patent applications)
Modes of temperature monitoring Air probe and algorithms
Temperature Range Ambient - 100°C
Temperature Accuracy + 0.1°C
Temperature Uniformity + 0.4°C
Thermal Gradient (for touch up and touch down amplifications) Range + 5°C, Accuracy + 0.4°C, Uniformity +0.4°C
Optical Detection
Excitation Source 12 x Ultra Bright Blue LED's and Detection and emission Filters
Filter 490nm Excitatin Filters
Detection 12 x Photodiodes
Emission Filter 535nm
Emissin Range Linear Dynamic Range of sample concentratin of at least 6 orders of magnitude
Operational Specifications
Operating Temperature 15-32°C ambient
Operating humidity 20-80%
Power supply 100/110/240V, 50/60Hz
Field use: 12V car battery, with 500W power inverter
Electrical Approvals IEC, CE
Input Power 400W
Communications ports USB2.0
Minimum Computer Requirement Windows XP/2000, 400 MHz processor, 256 color VGA monitor, 6GB hard drive, 6x CD-ROM drive, 128MB RAM, 1027 x768 pixel screen resolution.

 