Evocycler™ / Rapid Thermal Cycling System..
|
|
Rapid cycling, instant results. No more agarose gels!
Evocycler™ is a new concept in thermal cycler technology, combining experimental design with rapid amplification and end-point product analysis in one straightforward system. From simple preparative amlification and product validation through to SNP analysis and genotyping the Evocycler™ provides results, fast.
Rapid cycling with Exceptional Linearity
Evogen™ has moved away from the conventional slower peltier based technology, to design an efficient heating and cooling mechanism, which offers exceptionally linear heating and cooling dynamics. This technology coupled with the design of a unique high performance tube with ultra-thin walls and a high surface to volume ratio, yields ultra-rapid and uniform cycling performance.
|
| |
Optimised Tube Design
Superior Temperature Uniformity
Minimal Sample Lag
Improved Cycling times
Can be used with multiple chemistries and does not require BSA
Variable volumes of between 10µl and 100µl, for greater experimental flexibility.
Straight forward loading with standard pipette tips
Easy handling and storage. |
|
|
|
| |
| Technical Specifications |
| Sample Capacity |
12 wells |
| Sample Volume |
10µl - 100µl |
| Footprint |
300 x 170 x 210mm (W x H x D)
11 ¾ x 6¾ x 8¼inches (W x H x D) |
| Weight |
5kg/11lb |
| Heating - Ramp rates |
Max 5°C/sec, Min 0.05°C/sec |
| Method of Heating/Cooling |
Circulating air(subject to patent applications) |
| Modes of temperature monitoring |
Air probe and algorithms |
| Temperature Range |
Ambient - 100°C |
| Temperature Accuracy |
+ 0.1°C |
| Temperature Uniformity |
+ 0.4°C |
| Thermal Gradient (for touch up and touch down amplifications) |
Range + 5°C, Accuracy + 0.4°C, Uniformity +0.4°C |
| Optical Detection |
| Excitation Source |
12 x Ultra Bright Blue LED's and Detection and emission Filters |
| Filter |
490nm Excitatin Filters |
| Detection |
12 x Photodiodes |
| Emission Filter |
535nm |
| Emissin Range |
Linear Dynamic Range of sample concentratin of at least 6 orders of magnitude |
| Operational Specifications |
| Operating Temperature |
15-32°C ambient |
| Operating humidity |
20-80% |
| Power supply |
100/110/240V, 50/60Hz
Field use: 12V car battery, with 500W power inverter |
| Electrical Approvals |
IEC, CE |
| Input Power |
400W |
| Communications ports |
USB2.0 |
| Minimum Computer Requirement |
Windows XP/2000, 400 MHz processor, 256 color VGA monitor, 6GB hard drive, 6x CD-ROM drive, 128MB RAM, 1027 x768 pixel screen resolution. |
|
|
|